Photovoltaic Energy Storage Microgrid System (Container)
+
  • Photovoltaic Energy Storage Microgrid System (Container)

Photovoltaic Energy Storage Microgrid System (Container)

Commercial buildings and small industrial users: Manage electricity demand and save on electricity costs through peak and off-peak price differences. Rural villages not covered by the grid: Independent power supply combined with wind or solar power generation to provide stable electricity. Hospitals, data centers, communication base stations: Emergency backup power for critical facilities to maintain the operation of essential equipment. Situations requiring temporary power: Provide convenient mobile power solutions.

Key words:

Classification:

Case description

Product Overview

1. Commercial buildings and small industrial users: Manage electricity demand and save electricity costs through peak and off-peak price differences.
2. Villages in areas not covered by the grid: Independent power supply, combined with wind or solar power generation, to provide stable electricity.
3. Hospitals, data centers, communication base stations: Emergency backup power for important facilities to maintain the operation of critical equipment.
4. Occasions requiring temporary power: Provide convenient mobile power solutions.

Technical Parameters

Model

INEPS-225kW/430kWh

INEPS-500kW/1075kWh

Grid/Diesel Engine Side Parameters

Rated Power

225kW

500kW

Maximum Output Power

250kW

550kW

Grid Voltage

400V AC

400V AC

Frequency Range

50-60Hz

Rated AC Current

325A@45℃

722A@45℃

Current

≤3%

Can it operate off-grid?

Yes

Off-grid voltage distortion rate (linear load)

≤3%

Other Parameters

Grid Connection Type

3W+PE or 3W+N+PE

Grid and off-grid switching time/Diesel engine starting method

20ms/I/O

Topology

DC Bus

PCS Peak Efficiency

>=97.3%

Overload Capacity

110%, 1min; 120%, 10s

Fire Protection

Smoke sensor s/perfluoropropane fire extinguisher

Battery System

System Energy

430kWh

1075kWh

Nominal Capacity

2X280Ah

5X280Ah

Nominal Voltage/Battery Operating Voltage Range

768V/648V~864V

Maximum Charge and Discharge Current

280A

700A

Photovoltaic System

Maximum Input Power

225kW

500kW

Maximum Input Current

7X75A

16X75A

MPPT Channels

7

16

MPPT Power per Channel/Maximum Power

30KW/35kW

Start/Tracking Voltage Range

DC 200V/DC 250V-650V

System Parameters

Cooling Method

Liquid Cooling

Operating Humidity/Operating Temperature

0-95%/-20℃~+60℃

Noise/Protection Level

<65dB/IP54

Human-Machine Interface

HMI/Cloud Platform

Installation Method

Container

Total Weight

1200kg

1800kg

Dimensions (W*D*H)

10 feet

20 feet

Communication Method

RS485, CAN, Ethernet, dry contact

Isolation Method

Power frequency transformer isolation

Altitude

Up to 4000m (de-rated use above 2000m)

PCS Certification Standards

IEC 62477-1&IEC 61000-6-2, VDE-AR-N 4105, NRS 097-21-1:2017, GB/T34120-2017, GB/T34133-2017

Battery Certification Standards

UL1973, UL9540A, UN38.3, GB/T36276

  • 产品描述
    • Commodity name: Photovoltaic Energy Storage Microgrid System (Container)

    Commercial buildings and small industrial users: Manage electricity demand and save on electricity costs through peak and off-peak price differences. Rural villages not covered by the grid: Independent power supply combined with wind or solar power generation to provide stable electricity. Hospitals, data centers, communication base stations: Emergency backup power for critical facilities to maintain the operation of essential equipment. Situations requiring temporary power: Provide convenient mobile power solutions.

    Product Overview

    1. Commercial buildings and small industrial users: Manage electricity demand and save electricity costs through peak and off-peak price differences.
    2. Villages in areas not covered by the grid: Independent power supply, combined with wind or solar power generation, to provide stable electricity.
    3. Hospitals, data centers, communication base stations: Emergency backup power for important facilities to maintain the operation of critical equipment.
    4. Occasions requiring temporary power: Provide convenient mobile power solutions.

    Technical Parameters

    Model

    INEPS-225kW/430kWh

    INEPS-500kW/1075kWh

    Grid/Diesel Engine Side Parameters

    Rated Power

    225kW

    500kW

    Maximum Output Power

    250kW

    550kW

    Grid Voltage

    400V AC

    400V AC

    Frequency Range

    50-60Hz

    Rated AC Current

    325A@45℃

    722A@45℃

    Current

    ≤3%

    Can it operate off-grid?

    Yes

    Off-grid voltage distortion rate (linear load)

    ≤3%

    Other Parameters

    Grid Connection Type

    3W+PE or 3W+N+PE

    Grid and off-grid switching time/Diesel engine starting method

    20ms/I/O

    Topology

    DC Bus

    PCS Peak Efficiency

    >=97.3%

    Overload Capacity

    110%, 1min; 120%, 10s

    Fire Protection

    Smoke sensor s/perfluoropropane fire extinguisher

    Battery System

    System Energy

    430kWh

    1075kWh

    Nominal Capacity

    2X280Ah

    5X280Ah

    Nominal Voltage/Battery Operating Voltage Range

    768V/648V~864V

    Maximum Charge and Discharge Current

    280A

    700A

    Photovoltaic System

    Maximum Input Power

    225kW

    500kW

    Maximum Input Current

    7X75A

    16X75A

    MPPT Channels

    7

    16

    MPPT Power per Channel/Maximum Power

    30KW/35kW

    Start/Tracking Voltage Range

    DC 200V/DC 250V-650V

    System Parameters

    Cooling Method

    Liquid Cooling

    Operating Humidity/Operating Temperature

    0-95%/-20℃~+60℃

    Noise/Protection Level

    <65dB/IP54

    Human-Machine Interface

    HMI/Cloud Platform

    Installation Method

    Container

    Total Weight

    1200kg

    1800kg

    Dimensions (W*D*H)

    10 feet

    20 feet

    Communication Method

    RS485, CAN, Ethernet, dry contact

    Isolation Method

    Power frequency transformer isolation

    Altitude

    Up to 4000m (de-rated use above 2000m)

    PCS Certification Standards

    IEC 62477-1&IEC 61000-6-2, VDE-AR-N 4105, NRS 097-21-1:2017, GB/T34120-2017, GB/T34133-2017

    Battery Certification Standards

    UL1973, UL9540A, UN38.3, GB/T36276