Outdoor Cabinet for Solar Energy Storage Microgrid
Key words:
Classification:
Case description
Product Overview
1. Commercial buildings and small industrial users: Manage electricity demand and save electricity costs through peak and off-peak price differences.
2. Villages and farms not covered by the grid: Independent power supply combined with wind or solar power generation to provide stable electricity.
3. Hospitals, data centers, communication base stations: Emergency backup power for important facilities to maintain the operation of critical equipment.
4. Occasions requiring temporary power: Provide convenient mobile power solutions.
Technical Parameters
Model |
INEPS-30kW/60kWh |
INEPS-60kW/115kWh |
INEPS-125kW/215kWh |
Grid/Diesel Engine Side Parameters |
|||
Rated Power |
30kVA |
60kW |
125kW |
Maximum Output Power |
35KW |
70kW |
137kW |
Grid Voltage |
400V AC |
||
Frequency Range |
50~60Hz |
50~60Hz |
50~60Hz |
Rated AC Current |
45A@45℃ |
90A@45℃ |
180A@45℃ |
Current |
≤3% |
||
Can it operate off-grid? |
Yes |
||
Off-grid Voltage Distortion Rate (Linear Load) |
≤3% |
||
Other Parameters |
|||
Grid Connection Type |
3W+PE or 3W+N+PE |
||
Grid and Off-grid Switching Time |
20ms |
||
Diesel Engine Starting Method |
I/O |
||
Topology Method |
DC Bus |
||
PCS Peak Efficiency |
>=97.3% |
||
Overload Capacity |
110%, 1min; 120%, 10s |
||
Fire Protection |
Smoke Sensor/Perfluoropropane Fire Extinguisher |
||
Battery System |
|||
System Energy |
61.44kWh |
115.2KWh |
215.04kWh |
Nominal Capacity |
150Ah |
150Ah |
280Ah |
Nominal Voltage |
409V |
768V |
768V |
Battery Operating Voltage Range |
345V-396V |
648V-864V |
648V-864V |
Maximum Charge and Discharge Current |
75A |
75A |
140A |
Photovoltaic System |
|||
Maximum Input Power |
35kW |
70kW |
110kW |
Maximum Input Current |
75A |
150A |
300A |
MPPT Channels |
1 |
2 |
4 |
Power per MPPT Channel/Maximum Power |
30KW/35kW |
||
Starting Voltage/Tracking Voltage Range |
DC 200V/DC 250V-650V |
||
System Parameters |
|||
Cooling Method |
Liquid Cooling |
||
Noise/Protection Level |
<65dB/IP54 |
||
Operating Humidity/Operating Temperature |
0-95%/-20℃~+60℃ |
||
Human-Machine Interface |
HMI/Cloud Platform |
||
Installation Method |
Outdoor Cabinet |
||
Total Weight |
About 1200kg |
About 1800kg |
About 2800kg |
Dimensions (W"D*H) |
1100*1200*2200mm |
1600*1200*2200mm |
1600*1200*2200mm |
Communication Method |
RS485, CAN, Ethernet, dry contact |
||
Isolation Method |
Non-Isolated |
||
Altitude |
Up to 4000m (Derate use above 2000m) |
||
PCS Certification Standards |
IEC 62477-1&IEC 61000-6-2, VDE-AR-N 4105, NRS 097-21-1:2017, GB/T34120-2017, GB/T34133-2017 |
||
Battery Certification Standards |
UL1973, UL9540A, UN38.3, GB/T36276 |
- 产品描述
-
- Commodity name: Outdoor Cabinet for Solar Energy Storage Microgrid
Commercial buildings and small industrial users: Manage electricity demand and save on electricity costs through peak and off-peak price differences. Rural villages without grid coverage: Independent power supply combined with wind or solar power generation to provide stable electricity. Hospitals, data centers, communication base stations: Emergency backup power for critical facilities to maintain the operation of essential equipment. Temporary power supply situations: Provide convenient mobile power solutions.
Product Overview
1. Commercial buildings and small industrial users: Manage electricity demand and save electricity costs through peak and off-peak price differences.
2. Villages and farms not covered by the grid: Independent power supply combined with wind or solar power generation to provide stable electricity.
3. Hospitals, data centers, communication base stations: Emergency backup power for important facilities to maintain the operation of critical equipment.
4. Occasions requiring temporary power: Provide convenient mobile power solutions.Technical Parameters
Model
INEPS-30kW/60kWh
INEPS-60kW/115kWh
INEPS-125kW/215kWh
Grid/Diesel Engine Side Parameters
Rated Power
30kVA
60kW
125kW
Maximum Output Power
35KW
70kW
137kW
Grid Voltage
400V AC
Frequency Range
50~60Hz
50~60Hz
50~60Hz
Rated AC Current
45A@45℃
90A@45℃
180A@45℃
Current
≤3%
Can it operate off-grid?
Yes
Off-grid Voltage Distortion Rate (Linear Load)
≤3%
Other Parameters
Grid Connection Type
3W+PE or 3W+N+PE
Grid and Off-grid Switching Time
20ms
Diesel Engine Starting Method
I/O
Topology Method
DC Bus
PCS Peak Efficiency
>=97.3%
Overload Capacity
110%, 1min; 120%, 10s
Fire Protection
Smoke Sensor/Perfluoropropane Fire Extinguisher
Battery System
System Energy
61.44kWh
115.2KWh
215.04kWh
Nominal Capacity
150Ah
150Ah
280Ah
Nominal Voltage
409V
768V
768V
Battery Operating Voltage Range
345V-396V
648V-864V
648V-864V
Maximum Charge and Discharge Current
75A
75A
140A
Photovoltaic System
Maximum Input Power
35kW
70kW
110kW
Maximum Input Current
75A
150A
300A
MPPT Channels
1
2
4
Power per MPPT Channel/Maximum Power
30KW/35kW
Starting Voltage/Tracking Voltage Range
DC 200V/DC 250V-650V
System Parameters
Cooling Method
Liquid Cooling
Noise/Protection Level
<65dB/IP54
Operating Humidity/Operating Temperature
0-95%/-20℃~+60℃
Human-Machine Interface
HMI/Cloud Platform
Installation Method
Outdoor Cabinet
Total Weight
About 1200kg
About 1800kg
About 2800kg
Dimensions (W"D*H)
1100*1200*2200mm
1600*1200*2200mm
1600*1200*2200mm
Communication Method
RS485, CAN, Ethernet, dry contact
Isolation Method
Non-Isolated
Altitude
Up to 4000m (Derate use above 2000m)
PCS Certification Standards
IEC 62477-1&IEC 61000-6-2, VDE-AR-N 4105, NRS 097-21-1:2017, GB/T34120-2017, GB/T34133-2017
Battery Certification Standards
UL1973, UL9540A, UN38.3, GB/T36276
If you are interested in this product, please fill in the following information and submit it to us, we will arrange experts to contact us as soon as possible!
Related Products
Related Products